Add to Cart
60A 400A Digital Clamp Multimeter Auto Range For Factory / School
Digital Non-Invasive Inductive LED 4-in-1 Tester Wood Drywall Masonry Moisture Meter
Description
- The instrument is an professional measuring instrument with liquid crystal display and a back light source. The user readings in easily. Single hand operation with overload protection and low battery indicator. For professional, factory, school, lovers or family use, is an ideal Multi-function instrument.
- Used for AC DC voltage,AC current, frequency, resistance, capacitance measurement and the on-off circuit, measurement, temperature measurement .
- Automatic range
- Data keep
- Auto power off
- Relative measurement
Warranty
Please show your product certification when you need repair service or something wrong with items, it is effective show one and purchase invoice in together
1) Please contact with our company or repair service department when your clamp meter appear faults as soon as possible, don't delay your use and warranty period.
2) Our company provide warranty service for one year from the date of purchase.The company provides free warranty service after professional confirm the problem is not by user sabotage during the warranty period
3) Repair need charges (repairs components fee) more than the warranty period
4) All of the following will charge the cost of repair even in the warranty period.
⑴ Improper use or accidental disasters caused damage of components and circuit board burn
⑵ Non-professional personnel open shell, check and modification
⑶ Does not follow the instructions to operation caused problems
⑷ No maintenance and repair of the other company products
⑸ users offer the maintenance of postage and transportation fees
⑹ Clamp meter’s battery, probe, temperature probe and other functional accessories not included free warranty list
3.2.1 AC Current
Range | Resolution | Accuracy |
6A | 0.001A | ±(3.0% + 20) |
60A | 0.01A | ±(2.5% + 8) |
400A | 0.1A | ±(2.5% + 10) |
-Min input current:0.02A AC
- Max input:400A AC
- Frequency:45Hz ~65Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
3.2.2 DC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.5% + 3) |
60V | 0.01V | |
600V | 0.1V | ±(0.8% + 5) |
- Min/ input voltage:0.5VV DC
- Input impedance:10MW
-Maximum/ input voltage:600V AC (Effective value)OR 600V DC
3.2.4 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V |
±(1.0% + 5) |
60V | 0.01V | |
600V | 0.1V | ±(1.2% + 5) |
- Min/ input voltage:1.0V DC
-Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)or 600V DC
- Frequency range:45Hz ~65Hz
3.2.5 Frequency
3.2.5.1 Through the V file:
Range | Resolution | Accuracy |
60.0Hz | 0.1Hz | ±(1.0% + 5) |
1000Hz | 1Hz |
- Range:40Hz ~ 1000Hz
- Input range:≥ 0.2A AC(Effective value)
3.2.5.2 Through A File (From Clamp)
Range | Resolution | Accuracy |
60.0Hz | 0.1Hz | ±(1.0% + 5) |
1000Hz | 1Hz |
- Range:40Hz ~ 1000Hz
- Input range:≥ 1.0V AC(Effective value)
3.2.6 Resistance
Range | Resolution | Accuracy |
6kW | 0.001kW | ±(0.8% + 3) |
60kW | 0.01kW | |
600kW | 0.1kW | |
6MW | 0.001MW | ±(1.2% + 3) |
10MW | 0.1MW |
- Overload protection:600V DC or AC(Effective value)