SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

Shenzhen Xishen Development Co., Ltd.

Manufacturer from China
Active Member
5 Years
Home / Products / Handheld Digital Multimeter /

600V Auto Range Digital Multimeter 600uA 6000uA 0.1% 99% Duty Cycle

Contact Now
SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsEmily Tan
Contact Now

600V Auto Range Digital Multimeter 600uA 6000uA 0.1% 99% Duty Cycle

Ask Latest Price
Brand Name :CHX
Model Number :CHX-DM036
Certification :CE, RoHS
Place of Origin :CHINA
MOQ :10pc
Price :Negotiation
Payment Terms :T/T, Western Union,Paypal,L/C
Supply Ability :50000pcs/month
Delivery Time :5-35days
Packaging Details :1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg
Model :CHX-DM036
DC Voltage :6V/60V/600V
DC Current :600uA/6000uA/60mA/600mA/6A/10A
Duty Cycle :0.1% - 99%
Temperature :-20 to 1000°C, -4 to 1832°F
Working Temperature :-10~50℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Anemometer Anemometer Handheld Testo 405 Thermal Sensitivity Anemometer Wind Speed Meter

Product warranty instructions

Product certification is your instrument in the use of failure, seeking repair services must have, and then you purchase the invoice at the same time to be effective.

1) When your multimeter in use fails, please contact our maintenance department as soon as possible, consultation, so as not to delay your use and warranty period.

2) The product of the Company from the date of purchase from the warranty service. In the event of failure during the warranty period, the company professionals to confirm the reasons for the failure of non-users, the company free warranty service.

3) If the warranty period is exceeded, the cost will be charged (repair fee + component fee).

4) Even during the warranty period, maintenance fees are charged in the following cases.

Technical indicators

Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.

3.2.2 DC voltage

Range Resolution Accuracy
6V 0.001V ±(0.5% of reading + 5 words)
60V 0.01V
600V 0.1V ±(0.8% of reading + 5 words)

- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.


3.2.3 AC voltage

Range Resolution Accuracy
6V 0.001V ±(0.8% of reading + 3words)
60V 0.01V
600V 0.1V ±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.



3.2.4 Alternating current

Range Resolution Accuracy
600.0uA 0.1uA ±(1.5% of reading +10words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.5% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.

3.2.5 DC

Range Resolution Accuracy
600.0uA 0.1uA ±(1.0% of reading +5words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.0% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.


3.2.6 Frequency

Range Resolution Accuracy
9.999Hz 0.001Hz ±(1.0% of reading +3words)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99KHZ 0.01kHZ
999.9KHZ 0.1KHZ
9.999MHZ 0.001MHZ

- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)


3.2.7 Duty cycle

Range Resolution Accuracy
0.1 – 99.9% 0.1% ± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)

600V Auto Range Digital Multimeter 600uA 6000uA 0.1%  99% Duty Cycle

Resistance

Range Resolution Accuracy
600W 0.1W ±(0.8% of reading +3words)
6kW 0.001kW
60kW 0.01kW
600kW 0.1kW
6MW 0.001MW ±(1.2% of reading +3words)
60MW 0.01MW

- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)

Transistor test

Range Description Test Conditions
hFE The display reads the approximate value of hFE(0~1000) Base current of about 10uA; Vce about 2.8V

Capacitance

Range Resolution Accuracy
9.999nF 0.001nF ±(4.0% of reading +3words)
99.99nF 0.01nF
999.9nF 0.1nF
9.999mF 0.001mF
99.99mF 0.01mF
999.9mF 0.1mF
9.999mF 0.001mF ±(5.0% of reading +3words)
99.99mF 0.01mF Not calibrated

- Overload protection: 250V DC or AC (rms)

Temperature test

Range Accuracy Resolution
-20℃-300℃ ±(1.0%+4d) 1℃
301℃-1000℃ ±(1.9%+5d) 1℃
-4℉-600℉ ±(1.2%+6d) 1℉
601℉-1832℉ ±(1.9%+6d) 1℉

- Overload protection: 250V DC or AC (rms)

Inquiry Cart 0