Digital Anemometer Thermometer Wind Meter Anemometer Wind Analog Digital Anemometer
The Meter Structure
① Probe (NCV sensor)
② Flashlight
③ Signal indicator
④ Display
⑤ Power switch
⑥ sensitivity/Flashlight (With sensitivity indicator)
⑦ Battery cover
Technical specifications
operating voltage:
AC voltage :12~1000V,
50/60Hz
application environment:
operating temperature:0~40℃
Storage temperature:-10~50℃
Humidity:≤95%
Altitude:≤2000m
Safety Compliance:
CAT.III 1000V
CAT.IV 600V;CE
Battery:2×1.5V AAA
Replace the battery
Rotate the battery cover as shown below, then remove the old battery and install the new battery according to the positive and negative instructions of the battery.
Operation description
Power on/off
Press the power key and keep up for more than 1 second. The bee buzzed, the screen lit up and entered the test state. When the power on, power key was pressed and the bee turned to shut down.
High/low sensitivity
When the power is opened, the low sensitivity test state is defaults.
The sensitivity / flashlight key (less than 1 second) can be switched at high and low sensitivity. When the sensitivity indicator light is lit, it is a highly sensitive test state. Low sensitivity test state when extinguished
Notes:
High sensitivity:12~1000V
Low sensitivity: 48~1000V
Flashlight
Press the sensitivity / flashlight key and hold for more than 2 seconds. The flashlight is opened; The flashlight is closed by pressing the sensitivity / flashlight key and holding for more than 2 seconds.
No signal and no operation will be automatically closed after 3 minutes.
AC voltage detection
The voltage detector probe is placed near the AC voltage. When the voltage is induced, the signal light will be lit. The bargraph of the screen will become higher or lower as the voltage signal intensity is induced, and the beep beep hint will become faster or slower with the signal intensity.
Note 1: because the socket structure is different, when not by the backlight color change to distinguish the Live and neutral, generally according to the detected signal intensity to distinguish.
Note 2: Distinguish Live and neutral, if Live and neutral is near, the two lines can be separated as far as possible; it is true that it is not separable and can be distinguished according to the intensity of the signal. One of the strong signals is live wire and neutral wire with weak signal.
Auto power off
After about 3 minutes without any operation and No signal detection, the voltage detector will be automatically shut down to extend the battery life.
Low battery indicate
When the battery voltage drops to less than 2.5 volts, the display will display symbol. When the battery voltage drops to less than 2.3 volts, the voltage detector will automatically turn off. When low battery tip, please replace the battery.